Over the course of a career spanning industrial research facilities, healthcare campuses, and manufacturing operations, Tom Maxey has seen one challenge appear time and time again: steam trap failures are often overlooked, even though they can significantly impact energy use, operating costs, reliability, and system performance. 

Unlike a leaking valve or failed pump, steam trap failures aren’t always obvious. Energy can be lost for extended periods without disrupting operations, making the true cost difficult to recognize. 

Across multiple facilities and industries, Tom Maxey has found that organizations achieve the best results when steam trap surveys are treated as part of a long-term management strategy rather than a one-time maintenance activity.

The Failure Point Many Facilities Don't See

Steam traps play a critical role in steam system performance, but they are often one of the least visible failure points in a facility. 

“Most people don’t pay much attention to steam traps because it’s difficult to see the loss,” says Tom Maxey. “A leaking valve may be obvious. A failed pump gets immediate attention. But a failed steam trap can continue wasting energy day after day with no visible indication that anything is wrong.” 

Because steam losses often occur in the background, facilities can unknowingly increase energy consumption, operating costs, and maintenance demands. 

The impact extends well beyond the steam system itself. 

“Few projects touch as many organizational goals as a steam trap survey,” says Tom Maxey. “When you eliminate steam losses, you’re reducing fuel consumption, lowering emissions, improving system performance, increasing reliability, and reducing operating costs at the same time.” 

By uncovering hidden losses, steam trap surveys can support energy reduction, sustainability, reliability, safety, and cost-reduction initiatives across the facility. 

Consistency Delivers Results

Meaningful improvements rarely come from a single survey. They come from a consistent process of evaluating performance, correcting deficiencies, and repeating that process over time. 

Early in his career, Tom Maxey worked at a large industrial research and development facility where annual steam trap surveys were performed and identified failures were repaired or replaced. Over time, the results were significant. 

By consistently identifying and correcting failed traps, the facility reduced its failure rate from nearly one in four steam traps to less than five percent and maintained that level over time. 

“The survey is important, but the real value comes from taking action on the findings. Identifying failed traps and repairing them is what delivers the energy savings and reliability improvements.” 

The lesson followed Tom Maxey throughout his subsequent roles in healthcare and manufacturing facilities. Visibility alone doesn’t reduce energy consumption, improve reliability, or lower operating costs. Action does. 

When survey findings are paired with corrective action, facilities can reduce steam losses, improve reliability, support maintenance planning, and build a foundation for continuous improvement. 

Because visibility creates opportunity, but action creates results.

Year Steam Trap Failure Rate
Year 1 23.5%
Year 2 15%
Year 3 6.6%
Year 4 5.1%
Year 5 4.3%
Subsequent Years 3-5%

Why Specialized Expertise Matters

While the value of steam trap surveys remains clear, the way organizations execute those programs has changed. 

Throughout his career, Tom Maxey has observed a growing challenge across industries: fewer facilities have the internal resources and specialized expertise needed to conduct comprehensive steam trap surveys and complete the repairs that follow. 

“In this day and age, it’s rare for organizations to have the resources and expertise necessary to perform comprehensive steam trap surveys, let alone complete all of the repairs that follow.” 

For that reason, many organizations turn to specialists who focus on steam system assessments, testing, and repairs. 

Qualified providers bring: 

    • Established survey methodologies 
    • Specialized testing and diagnostic equipment 
    • Experience identifying steam system losses 
    • Consistent reporting and documentation 
    • The ability to prioritize and execute repairs efficiently 

More importantly, they help facilities turn information into action. 

“Organizations should focus on operating their facilities. Companies that perform steam trap surveys every day have the experience, equipment, and technical knowledge to identify issues quickly and help facilities achieve the results they’re looking for.” 

Successful steam trap management isn’t measured by the number of surveys completed. It’s measured by the energy savings, reliability improvements, and long-term performance gains that result from the actions taken afterward. 

When hot water runs too hot or too cold, people compensate—by turning temperatures up, washing longer, or re‑doing work. The heater burns extra fuel chasing unstable demand, and none of that extra energy improves results. Instead of delivering the right heat once, the system wastes energy trying to stay usable shift after shift.

Every degree of unnecessary overheating wastes fuel, puts added stress on heaters, creates safety risks, and leads to inconsistent sanitation. On the flip side, undershooting temperature causes crews to run washdown longer, re-clean areas, and lose confidence in the system. Both scenarios reduce overall efficiency.

Long-Term Success Requires More Than a Survey

Across research, healthcare, and manufacturing facilities, Tom Maxey has seen the same lesson reinforced time and time again: the greatest results come from combining visibility with action. 

“Steam trap surveys aren’t just about finding failed traps. They’re about reducing waste, improving efficiency, and ensuring the facility is operating the way it was intended to operate.” 

The organizations that see the greatest value don’t treat steam trap surveys as one-time projects. They use them as part of an ongoing strategy to improve efficiency, reliability, and long-term performance.

Bringing together two sides of steam system management: the facility experience of Tom Maxey and the technical expertise of Merlo Energy Technical Specialist Erich Knemeyer. Together, their perspectives provide practical insight into why consistent steam trap management, corrective action, and long-term planning matter.

Tom Maxey | Facility Management Professional

Tom Maxey has worked across industrial research, healthcare, and manufacturing facilities, supporting steam trap surveys, repairs, wireless monitoring, and ongoing steam trap management programs. His experience offers a firsthand perspective on how consistent steam trap management can support efficiency, reliability, and broader facility goals.


Erich Knemeyer | Technical Specialist at Merlo Energy

With over 33 years of experience in steam, condensate, and hot water systems, Erich Knemeyer possesses extensive knowledge and expertise in optimizing heating system efficiency. He holds a BS in Engineering Physics from Miami University in Ohio and has dedicated his career to assisting customers in troubleshooting their steam and heating systems. Currently, Erich collaborates with engineers and contractors, providing support in design development and the startup process.

The Importance of Steam Trap Management

Steam traps may be small, but overlooked failures can lead to wasted energy, higher costs, and operational issues. Learn why proactive steam trap management is an important part of maintaining an efficient, reliable steam system.

Steam Trap Survey

Discover what a steam trap survey can uncover. Identify failed traps, qunatify energy loss, and gain clear recommendations to help prioritize improvements and improve system performance.